Humidity-Freeze Test

Test condition

  • Temperature: -40±2℃, 85±2℃ (RH 85±5%)
  • Temperature change rate: 100℃/h (above 25℃), 200℃/h (below 25℃)
  • During Humidity-Freeze test set the continuous current flow as 0.5% Impp (STC Condition)

Requirements

a ) No evidence of major visual defects

b ) No interruption of current flow during the test

c ) Pass the insulation test (IEC 61215: 2005)

d ) Pass the wet leakage current test

e ) Max power degradation less than 5%